InfiniSolar V II 3KW
High PV voltage range
InfiniSolar VII is upgrade version for our InfiniSolar V first generation. This second generation inverter can accept high PV voltage range and this feature will facilitate PV system installation. Besides, battery independency feature will keep inverter running no matter battery is connected or not. We also offers parallel operation function up to 9 units for 2KW and 3KW. It offers high flexibility for future power expansion.
- Description
- Specifications
- Downloads
Description
InfiniSolar VII is upgrade version for our InfiniSolar V first generation. This second generation inverter can accept high PV voltage range and this feature will facilitate PV system installation. Besides, battery independency feature will keep inverter running no matter battery is connected or not. We also offers parallel operation function up to 9 units for 2KW and 3KW. It offers high flexibility for future power expansion.
Main Features
- Pure sine wave output
- High PV voltage range
- Self-consumption and feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable charging current and voltage
- Parallel operation up to 9 units only for 2KW/3KW model
- Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup
MODEL | InfiniSolar V II 1.5KW | InfiniSolar V II 2KW | InfiniSolar V II 3KW | |
---|---|---|---|---|
PHASE | 1-phase in / 1-phase out | 1-phase in / 1-phase out | 1-phase in / 1-phase out | |
Maximum PV Array Power | 2000W | 3000W | 4000W | |
Rated Output Power | 1500W | 2000W | 3000W | |
Maximum PV Array Open Circuit Voltage | 400 VDC | 450 VDC | 450 VDC | |
MPPT Range @ Operating Voltage | 120 VDC~380 VDC | 90 VDC~430 VDC | 120 VDC~430 VDC | |
Number of MPP Trackers | 1 | 1 | 1 | |
GRID-TIE OPERATION | ||||
GRID OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | 220/230/240 VAC | 220/230/240 VAC | |
Output Voltage Range | 184-264.5 VAC or 195.5-253 VAC (Selectable) | 184-264.5 VAC or 195.5-253 VAC (Selectable) | 184-264.5 VAC or 195.5-253 VAC (Selectable) | |
Nominal Output Current | 6.5A | 8.7A | 13A | |
Power Factor | > 0.99 | > 0.99 | > 0.99 | |
EFFICIENCY | ||||
Maximum Conversion Efficiency (DC/AC) | 95% | 95% | 95% | |
OFF-GRID, HYBRID OPERATION | ||||
BATTERY / CHARGER | ||||
Maximum AC Charge Current | 40A | 60 A | 60 A | |
Maximum Charging Current | 40A | 60 A | 60 A | |
Maximum Solar Charge Current | 30A | 60 A | 60 A | |
Nominal DC Voltage | 48 VDC | 48 VDC | 48 VDC | |
BATTERY MODE OUTPUT (AC) | ||||
Efficiency (DC to AC) | 93% | 93% | 93% | |
Nominal Output Voltage | 220/230/240 VAC | 220/230/240 VAC | 220/230/240 VAC | |
Output Waveform | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | |
GRID INPUT | ||||
Acceptable Voltage Range | 90-280 VAC or 170-280 VAC | 90-280 VAC or 170-280 VAC | 90-280 VAC or 170-280 VAC | |
Frequency Range | 60/50 Hz (Auto sensing) | 60/50 Hz (Auto sensing) | 60/50 Hz (Auto sensing) | |
Maximum AC Input Current | 30 A | 30 A | 40 A | |
AC Start-up Voltage / Auto Restart Voltage | 120-140 VAC / 180 VAC | 120-140 VAC / 180 VAC | 120-140 VAC / 180 VAC | |
GENERAL | ||||
PHYSICAL | ||||
Dimension, D X W X H (mm) | 100 x 300 x 440 | 120 x 295 x 468 | 120 x 295 x 468 | |
Net Weight (kgs) | 8 | 11 | 11 | |
INTERFACE | ||||
Communication Port | USB, RS-232 and Dry contact | USB, RS-232 and Dry contact | USB, RS-232 and Dry contact | |
Parallel Function | N/A | Yes, 9 units | Yes, 9 units | |
ENVIRONMENT | ||||
Operating Humidity | 0~90% RH (Non-condensing) | 0~90% RH (Non-condensing) | 0~90% RH (Non-condensing) | |
Operating Temperature | 0~50°C | 0~50°C | 0~50°C |
Brochure | InfiniSolar V II_Brochure | |