InfiniSolar-TX-PA-30KW

Popular

InfiniSolar-TX-PA-30KW

InfiniSolar-TX-PA-30KW

120,000.00

In stock

120,000.00

Parallel operation up to 4 units

This inverter is built in isolation transformer to provide pure power to connected devices. It also can be parallel operated with 4 units and expand the total capacity to 120KW. Users can easily expand their existing power rating by adding inverters.

  • Description
  • Specifications
  • Downloads

Description

This inverter is built in isolation transformer to provide pure power to connected devices. It also can be parallel operated with 4 units and expand the total capacity to 120KW. Users can easily expand their existing power rating by adding inverters.

Main Features

  • Pure sine wave output
  • Self-consumption and Feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • True galvanic isolation transformer design
  • User-adjustable charging current
  • Programmable multiple operation modes: Grid-tie, off-grid and
  • Grid-tie with backup
  • Built-in timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real-time status display and control
  • Parallel operation up to 4 units
MODEL InfiniSolar TX-PA 30KW
Maximum PV Input Power 45KW
Rated Output Power 30KW
Maximum Charging Power 30KW
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 950 VAC
Start-up Voltage / Initial Feeding Voltage 500 VDC / 550 VDC
MPP Voltage Range 460 VDC ~ 900 VDC
Number of MPP Trackers / Maximum Input Current 1 / 72 A
Full power MPP Voltage Range 625 VDC ~ 900 VDC
GRID OUTPUT (AC)
Output Frequency Range 49 ~ 51 Hz or 59.3 ~ 60.5 Hz
Nominal Output Voltage 230 VAC* (P-N) / 400 VAC (P-P)
Output Voltage Range 195.5 - 253 VAC per phase
Nominal Output Current 43.5 A per phase
Power Factor 1
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) 0.95
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 150 - 170 VAC per phase / 180 VAC per phase
Maximum AC Input Current 43.5 A per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
PV INPUT (DC)
Maximum DC Power / Maximum DC Voltage 45KW / 950 VDC
MPP Voltage Range 460 VDC ~ 900 VDC
Number of MPP Trackers / Maximum Input Current 1 / 72 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform Pure sine wave
Efficiency (DC to AC) >91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720KW /950 VDC
Start-up Voltage / Initial Feeding Voltage 500 VDC / 550 VDC
MPP Voltage Range 460 VDC ~ 900 VDC
Number of MPP Trackers / Maximum Input Current 1 / 72 A
GRID OUTPUT (AC)
Output Voltage Range 195.5 - 253 VAC per phase
Nominal Output Current 43.5 A per phase
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 150 - 170 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 43.5 A per phase
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Efficiency (DC to AC) >91%
BATTERY & CHARGER
Maximum Charging Current 80 A
Nominal Battery Voltage/Charging Voltage Range 384 VDC / 384 VDC ~ 480 VDC
GRID OUTPUT (AC)
Nominal Output Voltage 230 VAC* (P-N) / 400 VAC (P-P)
Output Frequency Range 49 ~ 51 Hz or 59.3 ~ 60.5 Hz
Power Factor 1
GENERAL
PHYSICAL
Dimension, D X W X H (mm) 430 x 715 x 1021
Net Weight (kgs) 223
INTERACE
Communication Port RS-232/USB
Intelligent Slot Optional SNMP, GPRS, WIFI, Modbus cards available
ENVIRONMENT
Humidity 0 ~ 90% RH (No condensing)
Operating Temperature -10 to 55°C
Altitude 0 ~ 1000 m**
PDF Download Brochure InfiniSolar TX-PA_DS